Konica Minolta CR-410 chroma meter
User-friendly, Portable Colorimeter With Unmatched Ruggedness & Application Flexibility
Chroma meter CR-410 is the successor to CR-310. It is more compact, more powerful and versatile then ever. The CR-410 is designed and built with a measurement area of Ø 50 mm. The CR-410 measurement head can perform measurement without connecting to the data processor DP-400. Full data compatability with the CR-310. What’s more, you can connect the measurement head directly to a PC by simply install the optional software and your PC can function as the data processor.
Konica Minolta CR-410 offer enhanced usability and functionality such as re-designed data process featuring a large backlit LCD screen for numerical or graphic display or measurement data, several new color spaces and PASS/FAIL formulas as well as indices for whiteness and yellowness enhance the usage into various filed of application. The new “user indices” function allows the input of up to 6 different user or application specific equations using XYZ, Yxy or CIELAB values. In addition it has larger memory storage capacity can store up to 100 targets and 2000 measurement.
The CR-410 has many accessories available to accommodate various types of application including powder, paste and opaque liquid samples.
APPLICATIONS:
Food | Plastic | Automotive Interior Parts | Ceramic | Granular Material | Furniture | Powder etc.
Chroma Meter CR-410
- Easy-to-use – menus and buttons are clear and easy-to-understand
- Portable – completely portable with battery power; or use the AC adapter. Measurements can be taken anywhere thanks to the light-weight design
- Data processor – measuring head can measure alone, or utilize advanced features with the data processor, and the unit features a high-speed printer for easy, on-site labeling
- User defined evaluation formulas – allows users to configure the color calculation formula and evaluation formula and as desired; useful for both customized formulas or industry-specific formulas
- Easy to upgrade – compatible with its predecessor, the CR-310, and takes functionality to a whole new level
- LCD screen – capable of displaying both pass/fail information and color-difference graphs
- Text entry – data processor allows the user to enter the names of calibration channels and color difference target colors, and users can input comments as well
- Six languages – German, Japanese, Spanish, Italian, French and English
- Stores Measurements – can store up to 1,000 measurements, or attach the data processor and store up to 2,000 measurements
- Calibration function – if the instrument needs to be calibrated it automatically notifies the user
- Abundant accessories – accessories are available for easy measurement of liquids, pastes, powders, and many other application types
Chroma Meter CR-410
Model | CR-410 Head |
---|---|
Name | Chroma Meters Measuring Head |
Illuminating/viewing system | Wide-area illumination/0° viewing angle; specular component included) |
Detector | Silicon photocells (6) |
Display range | Y: 0.01% to 160.00% (reflectance) |
Light source | Pulsed xenon lamp |
Measurement time | 1 sec. |
Minimum measurement interval | 3 sec. |
Battery performance | Approx. 800 measurements (when using batteries under Konica Minolta’s testing conditions) |
Measurement/illumination area | ⌀ 50mm/ ⌀ 53mm |
Repeatability | Within ΔE*ab 0.07 standard deviation (when the white calibration plate is measured 30 times at intervals of 10 seconds) |
Inter-instrument agreement | ΔE*ab: Within 0.8 Average of 12 BCRA Series II colors |
Observer | 2° Closely matches CIE 1931 Standard Observer ( x2λ, yλ, zλ) |
Illuminant *1 | C, D65 |
Display *1 | Chroma values, color difference values, PASS/WARN/FAIL display |
Tolerance judgement *1 | Color difference tolerance (box tolerance and elliptical tolerance) |
Color space/ colorimetric data | XYZ, Y x y, L*a*b*, Hunter Lab, L*C*h, Munsell (only illuminant C), CMC (l:c), CIE1994, Lab99, LCh99, CIE2000, CIE WI-Tw (only illuminant D65), WI ASTM E313 (only illuminant C), YI ASTM D1925 (only illuminant C), YI ASTM E313 (only illuminant C), User index (up to six can be registered from computer) |
Languages *1 | Operating keys: English LCD: English (default) (LCD: German, French, Italian, Spanish, Japanese) |
Storable data sets | 1000 (measureing head and data processor save different data) |
Color difference target colors | 100 |
Calibration channels *1 | 20 channels (ch00: white calibration, ch01 to ch19 : user calibration) |
Display | Dot-matrix LCD with back light (15 chars x 9 lines + 1 line for icon display) |
Interface | RS0232C compliant (for data processor/PC) *Baud rate: 4800, 9600, 19200 (bps) set at 9600 bps when shipped from factory |
Power source | 4 AA size alkaline or Ni-MH batteries, AC adapter AC120V 50-60Hz (for N.America and Japan) AC230V 50-60Hz (for worldwide except N.America) |
Size | 410: 102 (W) x 244 (H) x 63 (D) mm |
Weight | 410: Approx 570g (including 4 AAA size batteries and not including RS-232C cable) |
Operating temperature/Humidity Range | 0 to 40C, relative humidity 85% or less (at 35 C) with no condensation * Operating temperature/humidity range of products for North America : 5 to 40 C, relative humidity 80% or less (at 31 C) with no condensation |
Storage temperature/humidity range | -20 to 40 C, relative humidity 85% or less (at 35 C) with no condensation |
Other | LCD back light ON/OFF function (when ON< back light stays ON for 30 seconds after last key or measuremment operation) |
*1 indicates when connected to the Data Processor or when not set using the Data Processor or the optional software, that some of the function are not available when the measuring head is not connected. |
Name | Data Processor |
Model | DP-400 |
Display range | Y : 0.01 to 160.00% (reflectance) |
Measurement time *2 | 1 Seconds. |
Minimum measurement interval *2 | 3 Seconds. |
Battery performance | Approx. 800 measurements (when using batteries under company testing Konica Minolta’s conditions) |
Illuminants | C, D65 |
Display | Chroma values, color difference values, color difference graphs, PASS/WARN/FAIL display |
Tolerance judgment *2 | Color difference tolerance (box tolerance and elliptical tolerance) Only for the display function |
Color space/ colorimetric data | XYZ, Y x y, L*a*b*, Hunter Lab, L*C*h, Munsell (only illuminant C), CMC (l:c), CIE1994, Lab99, LCh99, CIE2000, CIE WI-Tw (only illuminant D65), WI ASTM E313 (only illuminant C), YI ASTM D1925 (only illuminant C), YI ASTM E313 (only illuminant C), User index (up to six registered in the Measuring Head can be used) |
Languages | Operating keys : English, LCD : English (default), German, French, Italian, Spanish, Japanese |
Storable data sets | Max. 2000 pieces of data (divisible into 100 pages) Deletion and Undoing selected stored data (one piece of data or all data) are possible |
Color difference target colors *2 | Only for the operating function (100 pieces of data when the measuring head is connected; input of measurement values or numeric) (independent of page function) |
Calibration channels *2 | Only for the operating function (20 channels when the measuring head is connected) (ch00: white calibration; ch01 to ch19: user calibration) |
Page function | 100 pages |
Display | Dot-matrix LCD with back light (16 chars x 9 lines + 1 line for icon display) Contrast adjustment |
Printer | 384 dot line thermal printer (can also print graphs) Automatically prints out all measurement results (can be set not to print) |
Statistical function | Maximum, minimum, average, and standard deviation |
Automatic measurement *2 | Date and time display: year, month, day, hour, minute Timer: 3seconds. to 99 minutes. (Some measurement modes require more than 3 seconds.) |
Interface | RS-232C compliant Baud rate (bps) : 19200 fixed (when connected to PC) When measuring head is connected baud rate is automatically set to that of the measurement head |
Power source | 4 AA size alkaline or Ni-MH batteries, AC adapter AC120V 50-60Hz (for N.America and Japan) AC230V 50-60Hz (for worldwide except N.America) |
Size | 100(W) x 73(H) x 255(D)mm |
Weight | Approx. 600g (not including batteries and paper) |
Operating temperature/Humidity Range | 0 to 40C, relative humidity 85% or less (at 35 C) with no condensation * Operating temperature/humidity range of products for North America : 5 to 40 C, relative humidity 80% or less (at 31 C) with no condensation |
Storage temperature/humidity range | -20 to 40 C, relative humidity 85% or less (at 35 C) with no condensation |
Other User | calibration function (multi-calibration/manual calibration) ∗2, Measurements for automatic average function, Print ON/OFF function. CR-400 measurement data import function ∗2, All color space print ON/OFF function, Data protection ON/OFF function. Back light ON/OFF function. Buzzer ON/OFF function. Display color limit function, Remote mode (stored data output), Character input function (alphanumeric) |
*2 indicates that part of or all functions are not available when the measurement head is not connected |