SPECTROPHOTOMETER CM-3610A

Konica Minolta Spectrophotometer CM-3610A
KONICA MINOLTA CM-3610A SPECTROPHOTOMETER

Built For Precision, Powerful Vertical Benchtop Spectrophotometer

The CM-3610A spectrophotometer is a successor to CM-3610d designed with outstanding performance utilize patented Innovative Optical System technology.

Konica Minolta CM-3610A specrtophotometer offers simultaneous measurement of specular component included (SCI) and specular component excluded (SCE) by eleminating mechanical switching and enables acquisition of SCI and SCE data through calculations with the measured data obtained using two light sources. In addition numerical UV control (NUVC) is the unsurpassed technology for UV adjustments when measuring samples containing optical brightening agent (OBA) such as textile, pulp, paper, paint and other chemicals.

The CM-3610A spectrophotometer with vertical alighment, unsurpassed technology and outstanding performance capable to measure a wide range of application such as textile, plastics ceramic, paint etc.

APPLICATIONS:
Paint | Printing | Plastics | Ceramics | Textile | Packaging | Granular Material etc

Spectrophotometer CM-3610A

  • Vertical design for easy handling of flimsy samples such as cloth and paper
  • Patented Numerical Gloss Control system for simultaneous SCI/SCE measurements
  • Patented Numerical UV Control for fast and reliable measurements of fluorescent materials
  • Piston-style sample holder
  • Sample viewer for accurate positioning
  • 3 measurement areas (Ø 4 mm, 8 mm, and 25.4 mm) to match any sample size

Spectrophotometer CM-3610A

ModelCM-3610A
Illumination/observation systemReflectance; di:8°, de:8° (diffused illumination, 8-degree viewing), equipped with simultaneous measurement of SCI (specular component included) / SCE (specular component excluded) Conforms to CIE No.15, lSO7724/1, ASTME1164, DIN5033 Teil7 and JIS Z8722 condition C standard; Transmittance: di:0°, de:0° (diffused illumination, 0-degree viewing) Conforms to CIE No.15, ASTME1164 and DIN5033 Teil7 standard.
Light receiving elementSilicon photodiode array (dual 40 elements)
Spectral separation deviceDiffraction grating
Wavelength range360 nm to 740 nm
Wavelength pitch10 nm
Half bandwidthApprox. 10 nm
Reflectance range0-200%, resolution 0.01%
Sphere sizeø152 mm
Light source4 pulsed xenon lamps
Minimum interval between measurementsNormal SCI/ SCE measurement: 4 sec. Transmittance measurement: 3 sec. UV-cut/ UV-adjusted measurement: 5 sec.
Measurement/illumination area(Selectable) LAV : ø25.4 mm/ ø30 mm MAV : ø8 mm/ ø11 mm SAV : ø4 mm/ ø7 mm
RepeatabilityWhen white calibration plate is measured 30 times at 10-sec. intervals after white calibration has been performed; Spectral reflectance: Standard deviation within 0.1% Colorimetric values: Standard deviation within E*ab 0.02
Inter instrument agreementMean ΔE*ab 0.15 (SCI) Average for 12 BCRA Series II color tiles compared to values measured with master body.
UV adjustmentInstantaneous numerical adjustment
UV cut filter400 nm cutoff and 420 nm cutoff
Transmittance chamberWidth: 133 mm; depth: approx. 50 mm; measurement dia.: approx. 17 mm; Transmission sample holder (Optional accessory): Sample holder (CM-A96) can only used only for plate shaped samples, not for liquid samples (removable)
InterfaceUSB 1.1
PowerAC100 to 240 V 50/60 Hz (Using included AC adapter)
Operating temperature/humidity range (*1)13 to 33°C, relative humidity 80% or less (at 35°C) with no condensation
Storage temperature/humidity range0 to 40°C, relative humidity 80% or less (at 35°C) with no condensation
Size (WxHxD)CM-3610A 300 x 597 x 315 mm
WeightCM-3610A 16.5 kg

*1 Operating temperature/humidity range of products for North America : 13 to 33°C, relative humidity 80% or less (at 31°C) with no condensation