PROMETRIC® I SERIES IMAGING PHOTOMETER

prometric i
RADIANT VISION SYSTEMS PROMETRIC® I IMAGING COLORIMETER

World’s Fastest, Highly Accurate and High-Resolution Imaging Colorimeters

Radiant Vision  Systems ProMetric® I family of imaging colorimeters is built and designed to address the demands for high-volume manufacturing of displays, illuminated keyboards and LED lighting products. 

Radiant Vision Systems ProMetric I delivers the required performance for highly accurate color and luminance measurements in an automated manufacturing environment. ProMetric I imaging colorimeter offers resolution from 2 megapixels in the I2 up to 29 megapixels in the I29. These sensors enable pixel-level measurements of displays, inter- and intra-character luminance measurements on lighted keyboards, and accurate measurements of LED luminance and color in luminaires with large LED arrays.

Radiant Vision Systems ProMetric I supports high-speed USB and Ethernet communications, providing highly reliable operation over long distances, even in the most demanding manufacturing environments

ProMetric I is optimized to work with the industry-leading TrueTest™ Automated Visual Inspection Software from Radiant. TrueTest provides a complete, turnkey solution for high-volume manufacturing of displays, illuminated keyboards and lighting products, with test sequencing interface to perform multiple inspections in-line in a matter of seconds. Whether you need to increase your test coverage or reduce test time for automated visual inspection, ProMetric I is designed specifically for your application. Learn more

APPLICATIONS
Color and luminance testing of displays | Light measurement and characterization of LED products | Appearance uniformity testing of illuminated instrument clusters and keypads

Radiant Vision Systems PROMETRIC® I 

  • High-speed, high-resolution, interline-cooled CCDs, with better than 61dB dynamic range
  • CIE-matched color filters and neutral density filters, closely matches human visual perception
  • Multiple lens choices with Smart Calibration™ for a wide range of distance and aperture settings
  • Comes standard with Radiant ProMetric Software for light analysis and camera control
  • Works seamlessly with Radiant TrueTest Automated Visual Inspection test sequencing platform for automated applications

System Recommendations

  • 3.0 GHz and 8 cores
  • 16 – 32 GB RAM
  • Windows 7 or 10, 64 bits
  • Dual-monitor video output
  • Ethernet 100/1000 or USB 2.0

Radiant Vision Systems PROMETRIC® I2

ParameterProMetric I2
Primary ApplicationUniformity Testing, NFMS, ProMetric in R&D Setting
CCD Pixel Resolution1600 x 1200
CCD Megapixels1.9
CCD TypeInterline, Cooled to +5°C
System Dynamic Range
(single exposure, per pixel)
61 dB( 1 x 1 binning)
High Dynamic Range
(multi-exposure)
>1,000,000:1
Luminance (Minimum)*0.00001 cd/m² Limit of Detection
0.0001 cd/m²@ SNR = 60
0.0005 cd/m²@ SNR = 100
Luminance (Maximum)10¹⁰ cd/m² with optional ND filters
System Accuracy**Illuminance ±3%; Luminance (Y) ±3%; Color Coordinates (x,y) ±0.003
Short-term Repeatability*Illuminance ±0.02%; Luminance (Y) ±0.02%; Color Coordinates (x,y) ±0.0005
Lens Type / Focal Distance
Available
Electronically controlled focus and aperture;
24, 35, 50, 100, 200 mm
Field of View
(Full Angle, H x V degrees)
24 mm 20° x 15°
35 mm 14° x 10°
50 mm 10° x 8°
100 mm 5° x 4°
200 mm 3° x 2°
Minimum Meaasurement time¹0.3 sec – photopic
1.1 sec – color
Spatial Measurement CapabilitiesLuminance, Radiance, Illuminance, Irradiance, Luminous Intensity, Radiant Intensity,
CIE Chromaticity Coordinates, L*a*b* Color Scale,
Correlated Color Temperature (CCT), Dominant Wavelength
Unitsfoot-lambert, cd/m2, nit, W/sr/m2, foot-candles, lux, lux-s, W/m2, W-s/m2, candela, W/sr.
CIE (x, y) and (u’, v’), Kelvin (CCT)
Communication InterfaceEthernet 100/1000, USB 2.0
Power100 ~ 240V, 50 ~ 60 Hz, 140W
LCD Touch Panel238 mm x 181 mm x 230 mm
Dimension ( H x W x D)Resolution: 800 x 600; Diagonal: 125mm
Weight4.9 kg
Operating Temperature0 ~30°C
Operating Humidity20 ~ 70% non condensing

Specifications subject to change without notice.
¹ For 100 cd/m², using gigabit Ethernet
* Based on a virtual detector size of 1% of FOV.
** Based on illuminant A or user calibration for specific spectra. Based on a virtual detector size of 1% of the FOV.

Radiant Vision Systems PROMETRIC® I8

ParameterProMetric I8
Primary ApplicationProduction Line Testing, Display Testing, Color Correction
CCD Pixel Resolution3296 x 2472
CCD Megapixels8.1
CCD TypeInterline, Cooled to +5°C
System Dynamic Range
(single exposure, per pixel)
61 dB( 1 x 1 binning)
High Dynamic Range
(multi-exposure)
>1,000,000:1
Luminance (Minimum)*0.00001 cd/m² Limit of Detection
0.0001 cd/m²@ SNR = 60
0.0005 cd/m²@ SNR = 100
Luminance (Maximum)10¹⁰ cd/m² with optional ND filters
System Accuracy**Illuminance ±3%; Luminance (Y) ±3%; Color Coordinates (x,y) ±0.003
Short-term Repeatability*Illuminance ±0.02%; Luminance (Y) ±0.02%; Color Coordinates (x,y) ±0.0005
Lens Type / Focal Distance
Available
Electronically controlled focus and aperture;
24, 35, 50, 100, 200 mm
Field of View
(Full Angle, H x V degrees)
24 mm 38° x 30°
35 mm 29° x 22°
50 mm 21° x 16°
100 mm 10° x 8°
200 mm 5° x 4°
Minimum Meaasurement time¹0.4 sec – photopic
1.2 sec – color
Spatial Measurement CapabilitiesLuminance, Radiance, Illuminance, Irradiance, Luminous Intensity, Radiant Intensity,
CIE Chromaticity Coordinates, L*a*b* Color Scale,
Correlated Color Temperature (CCT), Dominant Wavelength
Unitsfoot-lambert, cd/m2, nit, W/sr/m2, foot-candles, lux, lux-s, W/m2, W-s/m2, candela, W/sr.
CIE (x, y) and (u’, v’), Kelvin (CCT)
Communication InterfaceEthernet 100/1000, USB 2.0
Power100 ~ 240V, 50 ~ 60 Hz, 140W
LCD Touch Panel238 mm x 181 mm x 230 mm
Dimension ( H x W x D)Resolution: 800 x 600; Diagonal: 125mm
Weight4.9 kg
Operating Temperature0 ~30°C
Operating Humidity20 ~ 70% non condensing

Specifications subject to change without notice.
¹ For 100 cd/m², using gigabit Ethernet
* Based on a virtual detector size of 1% of FOV.
** Based on illuminant A or user calibration for specific spectra. Based on a virtual detector size of 1% of the FOV.

Radiant Vision Systems PROMETRIC® I16

ParameterProMetric I16
Primary ApplicationProduction Line Testing, Display Testing, Color Correction
CCD Pixel Resolution4896 x 3264
CCD Megapixels16
CCD TypeInterline, Cooled to +5°C
System Dynamic Range
(single exposure, per pixel)
61 dB( 1 x 1 binning)
High Dynamic Range
(multi-exposure)
>1,000,000:1
Luminance (Minimum)*0.00001 cd/m² Limit of Detection
0.0001 cd/m²@ SNR = 60
0.0005 cd/m²@ SNR = 100
Luminance (Maximum)10¹⁰ cd/m² with optional ND filters
System Accuracy**Illuminance ±3%; Luminance (Y) ±3%; Color Coordinates (x,y) ±0.003
Short-term Repeatability*Illuminance ±0.02%; Luminance (Y) ±0.02%; Color Coordinates (x,y) ±0.0005
Lens Type / Focal Distance
Available
Electronically controlled focus and aperture;
35, 50, 100, 200 mm
Field of View
(Full Angle, H x V degrees)
35 mm 41° x 28°
50 mm 30° x 20°
100 mm 15° x 10°
200 mm 8° x 5°
Minimum Meaasurement time¹0.6 sec – photopic
1.5 sec – color
Spatial Measurement CapabilitiesLuminance, Radiance, Illuminance, Irradiance, Luminous Intensity, Radiant Intensity,
CIE Chromaticity Coordinates, L*a*b* Color Scale,
Correlated Color Temperature (CCT), Dominant Wavelength
Unitsfoot-lambert, cd/m2, nit, W/sr/m2, foot-candles, lux, lux-s, W/m2, W-s/m2, candela, W/sr.
CIE (x, y) and (u’, v’), Kelvin (CCT)
Communication InterfaceEthernet 100/1000, USB 2.0
Power100 ~ 240V, 50 ~ 60 Hz, 140W
LCD Touch Panel238 mm x 181 mm x 230 mm
Dimension ( H x W x D)Resolution: 800 x 600; Diagonal: 125mm
Weight4.9 kg
Operating Temperature0 ~30°C
Operating Humidity20 ~ 70% non condensing

Specifications subject to change without notice.
¹ For 100 cd/m², using gigabit Ethernet
* Based on a virtual detector size of 1% of FOV.
** Based on illuminant A or user calibration for specific spectra. Based on a virtual detector size of 1% of the FOV.

Radiant Vision Systems PROMETRIC® I29

ParameterProMetric I29
Primary ApplicationProduction Line Testing, Display Testing, Color Correction
CCD Pixel Resolution6576 x 4384
CCD Megapixels28.8
CCD TypeInterline, Cooled to +5°C
System Dynamic Range
(single exposure, per pixel)
61 dB( 1 x 1 binning)
High Dynamic Range
(multi-exposure)
>1,000,000:1
Luminance (Minimum)*0.00001 cd/m² Limit of Detection
0.0001 cd/m²@ SNR = 60
0.0005 cd/m²@ SNR = 100
Luminance (Maximum)10¹⁰ cd/m² with optional ND filters
System Accuracy**Illuminance ±3%; Luminance (Y) ±3%; Color Coordinates (x,y) ±0.003
Short-term Repeatability*Illuminance ±0.02%; Luminance (Y) ±0.02%; Color Coordinates (x,y) ±0.0005
Lens Type / Focal Distance
Available
Electronically controlled focus and aperture;
50, 100, 200 mm
Field of View
(Full Angle, H x V degrees)
50 mm 40° x 28°
100 mm 20° x 14°
200 mm 11° x 7°
Minimum Meaasurement time¹0.9 sec – photopic
2.4 sec – color
Spatial Measurement CapabilitiesLuminance, Radiance, Illuminance, Irradiance, Luminous Intensity, Radiant Intensity,
CIE Chromaticity Coordinates, L*a*b* Color Scale,
Correlated Color Temperature (CCT), Dominant Wavelength
Unitsfoot-lambert, cd/m2, nit, W/sr/m2, foot-candles, lux, lux-s, W/m2, W-s/m2, candela, W/sr.
CIE (x, y) and (u’, v’), Kelvin (CCT)
Communication InterfaceEthernet 100/1000, USB 2.0
Power100 ~ 240V, 50 ~ 60 Hz, 140W
LCD Touch Panel238 mm x 181 mm x 230 mm
Dimension ( H x W x D)Resolution: 800 x 600; Diagonal: 125mm
Weight4.9 kg
Operating Temperature0 ~30°C
Operating Humidity20 ~ 70% non condensing

Specifications subject to change without notice.
¹ For 100 cd/m², using gigabit Ethernet
* Based on a virtual detector size of 1% of FOV.
** Based on illuminant A or user calibration for specific spectra. Based on a virtual detector size of 1% of the FOV.