PROMETRIC® Y SERIES IMAGING PHOTOMETER

prometric y
RADIANT VISION SYSTEMS PROMETRIC® Y IMAGING PHOTOMETER

High-Performance Imaging Photometers Designed For Display Test And Cosmetic Inspection In Production Environments

Radiant Vision Systems ProMetric® Y series is a high-performance imaging photometers designed and built for high-volume production testing of displays, smartphones, tablets, notebooks, keyboards, and lighting products.

It uses a scientific-grade 2-megapixel (1600 x 1200) CCD sensor that is thermoelectrically cooled to provide accurate, repeatable 12-bit measurements. The Y16 provides more resolution with a 16-megapixel (4896 x 3264) CCD sensor. The Y29 provides even higher resolution with a 29-megapixel (6576 x 4384) CCD sensor. The Y43 provides the highest resolution with a 43-megapixel (8040 x 5360) CCD sensor. Each ProMetric Y supports high-speed USB and Ethernet communications.

ProMetric software includes API support, and provides complete measurement control and Point-of-Interest/Region-of-Interest functionality. In addition, the ProMetric Y imaging photometers are backed by the industry’s best product warranty, including direct access to the Radiant Vision Systems technical support team to maximize the utility of your application. For automated testing, ProMetric Y is optimized to work with the industry-leading TrueTest Software—and specialized software modules—for high-volume manufacturing of displays, smartphones, notebooks and more. Learn more

APPLICATIONS
Display Testing | Backlit Symbols | Cosmetics Surface Defects

Radiant Vision Systems PROMETRIC® Y 

  • High Speed: Minimum measurement time (photopic) to 0.3 seconds
  • High resolution, to 43 megapixels
  • IR measurements, using the IR-PMY2, IR-PMY16, and IR-PMY29, and IP-PMY43 Radiometer models
  • Multiple lens options: 20 mm, 35 mm, 50 mm, 100 mm macro, and 200 mm
  • ProMetric control and analysis software is standard. TrueTest™ Automated Visual Inspection Software and other software modules optional.

System Recommendations

  • 3.0 GHz and 8 cores
  • 16 – 32 GB RAM
  • Windows 7 or 10, 64 bits
  • Dual-monitor video output
  • Ethernet 100/1000 or USB 2.0

Radiant Vision Systems PROMETRIC® Y2

ParameterProMetric Y2
Primary ApplicationProduction Line Testing, Lighting
CCD Pixel Resolution1600 x 1200
CCD Megapixels1.9
CCD TypeInterline, Cooled to +5°C
System Dynamic Range
(single exposure, per pixel)
61 dB( 1 x 1 binning)
High Dynamic Range
(multi-exposure)
>1,000,000:1
Luminance (Minimum)*0.00001 cd/m² Limit of Detection
0.0001 cd/m²@ SNR = 60
0.0005 cd/m²@ SNR = 100
Luminance (Maximum)10¹⁰ cd/m² with optional ND filters
System Accuracy**Illuminance ±3%; Luminance (Y) ±3%
Short-term Repeatability*Illuminance ±0.02%; Luminance (Y) ±0.02%
Lens Type / Focal Distance
Available
Electronically controlled focus and aperture;
24, 35, 50, 100, 200 mm
Field of View
(Full Angle, H x V degrees)
24 mm 20° x 15°
35 mm 14° x 10°
50 mm 10° x 8°
100 mm macro 5° x 4°
200 mm 3° x 2°
Minimum Meaasurement Time
(for 100 cd/m²
0.2 sec
Spatial Measurement CapabilitiesLuminance, Radiance, Illuminance, Irradiance, Luminous Intensity, Radiant Intensity
Unitsfoot-lambert, cd/m², nit, W/sr/m², foot-candles, lux, lux-s, W/m², W-s/m², candela, W/sr.
Communication InterfaceEthernet 100/1000, USB 2.0
Power100 ~ 240V, 50 ~ 60 Hz, 140W
LCD Touch Panel238 mm x 181 mm x 230 mm
Dimension ( H x W x D)Resolution: 800 x 600; Diagonal: 125mm
Weight4.9 kg
Operating Temperature0 ~30°C
Operating Humidity20 ~ 70% non condensing

Specifications subject to change without notice.
¹ With 35 mm USM lens, use AA2000 67-72 mm adaptor and 72 mm filter.
  With 50 mm USM lens, use AA2000 67-72 mm adaptor with 72 mm filter.
  With 100 mm Macro lens, use AA1040 58-52 mm adaptor and 72 mm filter.
  With 200 mm lens, use 72 mm filter.
* Based on a virtual detector size of 1% of the FOV.
** Based on illuminant A or user calibration for specific spectra. Based on a virtual detector size of 1% of the FOV.

 

Radiant Vision Systems PROMETRIC® Y16 

ParameterProMetric Y16
Primary ApplicationProduction Line Testing, Display Testing, OLED Testing, Advanced Vision
CCD Pixel Resolution4896 x 3264
CCD Megapixels16
CCD TypeInterline, Cooled to +5°C
System Dynamic Range
(single exposure, per pixel)
61 dB( 1 x 1 binning)
High Dynamic Range
(multi-exposure)
>1,000,000:1
Luminance (Minimum)*0.00001 cd/m² Limit of Detection
0.0001 cd/m²@ SNR = 60
0.0005 cd/m²@ SNR = 100
Luminance (Maximum)10¹⁰ cd/m² with optional ND filters
System Accuracy**Illuminance ±3%; Luminance (Y) ±3%
Short-term Repeatability*Illuminance ±0.02%; Luminance (Y) ±0.02%
Lens Type / Focal Distance
Available
Electronically controlled focus and aperture;
35, 50, 100, 200 mm
Field of View
(Full Angle, H x V degrees)
35 mm 41° x 28°
50 mm 30° x 20°
100 mm macro 15° x 10°
200 mm 8° x 5°
Minimum Meaasurement Time
(for 100 cd/m²
0.6 sec
Spatial Measurement CapabilitiesLuminance, Radiance, Illuminance, Irradiance, Luminous Intensity, Radiant Intensity
Unitsfoot-lambert, cd/m², nit, W/sr/m², foot-candles, lux, lux-s, W/m², W-s/m², candela, W/sr.
Communication InterfaceEthernet 100/1000, USB 2.0
Power100 ~ 240V, 50 ~ 60 Hz, 140W
LCD Touch Panel238 mm x 181 mm x 230 mm
Dimension ( H x W x D)Resolution: 800 x 600; Diagonal: 125mm
Weight4.9 kg
Operating Temperature0 ~30°C
Operating Humidity20 ~ 70% non condensing

Specifications subject to change without notice.
¹ With 35 mm USM lens, use AA2000 67-72 mm adaptor and 72 mm filter.
  With 50 mm USM lens, use AA2000 67-72 mm adaptor with 72 mm filter.
  With 100 mm Macro lens, use AA1040 58-52 mm adaptor and 72 mm filter.
  With 200 mm lens, use 72 mm filter.
* Based on a virtual detector size of 1% of the FOV.
** Based on illuminant A or user calibration for specific spectra. Based on a virtual detector size of 1% of the FOV.

Radiant Vision Systems PROMETRIC® Y29

ParameterProMetric Y29
Primary ApplicationProduction Line Testing, Display Testing, OLED Testing, Advanced Vision
CCD Pixel Resolution6576 x 4384
CCD Megapixels28.8
CCD TypeInterline, Cooled to +5°C
System Dynamic Range
(single exposure, per pixel)
61 dB( 1 x 1 binning)
High Dynamic Range
(multi-exposure)
>1,000,000:1
Luminance (Minimum)*0.00001 cd/m² Limit of Detection
0.0001 cd/m²@ SNR = 60
0.0005 cd/m²@ SNR = 100
Luminance (Maximum)10¹⁰ cd/m² with optional ND filters
System Accuracy**Illuminance ±3%; Luminance (Y) ±3%
Short-term Repeatability*Illuminance ±0.02%; Luminance (Y) ±0.02%
Lens Type / Focal Distance
Available
Electronically controlled focus and aperture;
35, 50, 100, 200 mm
Field of View
(Full Angle, H x V degrees)
35 mm 55° x 37°
50 mm 40° x 28°
100 mm macro 20° x 14°
200 mm 11° x 7°
Minimum Meaasurement Time
(for 100 cd/m²
1.0 sec
Spatial Measurement CapabilitiesLuminance, Radiance, Illuminance, Irradiance, Luminous Intensity, Radiant Intensity
Unitsfoot-lambert, cd/m², nit, W/sr/m², foot-candles, lux, lux-s, W/m², W-s/m², candela, W/sr.
Communication InterfaceEthernet 100/1000, USB 2.0
Power100 ~ 240V, 50 ~ 60 Hz, 140W
LCD Touch Panel238 mm x 181 mm x 230 mm
Dimension ( H x W x D)Resolution: 800 x 600; Diagonal: 125mm
Weight4.9 kg
Operating Temperature0 ~30°C
Operating Humidity20 ~ 70% non condensing

Specifications subject to change without notice.
¹ With 35 mm USM lens, use AA2000 67-72 mm adaptor and 72 mm filter.
  With 50 mm USM lens, use AA2000 67-72 mm adaptor with 72 mm filter.
  With 100 mm Macro lens, use AA1040 58-52 mm adaptor and 72 mm filter.
  With 200 mm lens, use 72 mm filter.
* Based on a virtual detector size of 1% of the FOV.
** Based on illuminant A or user calibration for specific spectra. Based on a virtual detector size of 1% of the FOV.

Radiant Vision Systems PROMETRIC® Y43

ParameterProMetric Y43
Primary ApplicationProduction Line Tesitng, Display Testing, Color Correction
CCD Pixel Resolution8040 x 5360
CCD Megapixels43.1
CCD TypeInterline, Cooled to +5°C
System Dynamic Range
(single exposure, per pixel)
59 dB( 1 x 1 binning)
High Dynamic Range
(multi-exposure)
>1,000,000:1
Luminance (Minimum)*0.00001 cd/m² Limit of Detection
0.0001 cd/m²@ SNR = 60
0.0005 cd/m²@ SNR = 100
Luminance (Maximum)10¹⁰ cd/m² with optional ND filters
System Accuracy**Illuminance ±3%; Luminance (Y) ±3%
Short-term Repeatability*Illuminance ±0.02%; Luminance (Y) ±0.02%
Lens Type / Focal Distance
Available
Electronically controlled focus and aperture;
35, 50, 100, 200 mm
Field of View
(Full Angle, H x V degrees)
35 mm 55° x 37°
50 mm 40° x 28°
100 mm macro 20° x 14°
200 mm 11° x 7°
Minimum Meaasurement Time
(for 100 cd/m²
1.4 sec
Spatial Measurement CapabilitiesLuminance, Radiance, Illuminance, Irradiance, Luminous Intensity, Radiant Intensity
Unitsfoot-lambert, cd/m², nit, W/sr/m², foot-candles, lux, lux-s, W/m², W-s/m², candela, W/sr.
Communication InterfaceEthernet 100/1000, USB 2.0
Power100 ~ 240V, 50 ~ 60 Hz, 140W
LCD Touch Panel238 mm x 181 mm x 230 mm
Dimension ( H x W x D)Resolution: 800 x 600; Diagonal: 125mm
Weight4.9 kg
Operating Temperature0 ~30°C
Operating Humidity20 ~ 70% non condensing

Specifications subject to change without notice.
¹ With 35 mm USM lens, use AA2000 67-72 mm adaptor and 72 mm filter.
  With 50 mm USM lens, use AA2000 67-72 mm adaptor with 72 mm filter.
  With 100 mm Macro lens, use AA1040 58-52 mm adaptor and 72 mm filter.
  With 200 mm lens, use 72 mm filter.
* Based on a virtual detector size of 1% of the FOV.
** Based on illuminant A or user calibration for specific spectra. Based on a virtual detector size of 1% of the FOV.